SGScan-X V1.23E Updater


                                                                                13/7/2005
 

This program upgrades SGScan-X V1.20 or V1.21 or V1.22 to V1.23.
The modifications included in this program are shown below.
Please update the software after you read the following instructions.
Be careful that this program cannot upgrade SGScan-X V1.0x orV1.1x to V1.23.

=======================================================
- Modification
=======================================================

  Changes in Version 1.23
Problems and improved items


<Problems in Ver. 1.22 and their corrections in Ver. 1.23>

 

- Function of adding ICC profile

 The function of "Add this profile to the image (TIFF)" individually can add each profile to each color mode, CMYK, RGB or Gray.

 

- Zoom-in prescan order

A zoom-in prescan is performed in following order.

 

- Auto trimming ON

A zoom-in prescan performs in an order from the trimming frame in the upper part of a full prescan window.

- Auto trimming OFF

A zoom-in prescan performs in the order that created the trimming frame on the full prescan window.

 

- The stability of application

 

- In Scanning, when a folder to save image of PICT or CT image format is lost, the problem that the application is quitted abnormally has been improved.

 

- The stability of SCSI I/F has been improved.

 

- When application is quitted, if the folder specified as the preservation place is lost, the problem that the application doesn't quit normally has been improved.

 

 

<Problems in Ver. 1.21 and their corrections in Ver. 1.22>

 

- The reference data for RGB scan

The reference data is corrected. In detail, please refer to "RGB Input Manual (SG).pdf"

- Correction

AI function of former reference data for RGB scan, is set to off.

AI function is not necessary to use for following reference data.

- T AdobeRGB      - T sRGB

- R AdobeRGB     - R sRGB

 

- Addition

Reference data for AdobeRGB and sRGB, which is necessary to use AI function, is added.

- T AdobeRGB(AI)            - T sRGB(AI)

- R AdobeRGB(AI)            - R sRGB(AI)

 

- The response of application

The problem, which is temporarily lost of response of application at the end of scan, has been solved.

 

- The stability of application

The stability of following items is improved.

- SCSI I/F

- Saving of TIFF image

 

- Scan of large size image

At the end of scan of large size image, the error message is occasionally displayed as follows.

"A-I164: Image is too big. Please set size of image to small."

The excess of resource information causes the error, which is preview data.

In order to solve this problem, the application is modified to save only image data.

 

- Adaptec Power Domain 29160N SCSI Card Driver

The driver software of PowerDomain 29160N SCSI V1.30 is bundled in "Goodies" folder in CD.

But, please care about the version of driver software.


<Problems in Ver. 1.20 and their corrections in Ver. 1.21>


- Application's response
The malfunction that the response of the application is temporarilylost before next scanning in the continues scanning has been revised.

- Loading parameter file
When an old parameter file was loaded, the problem that the applicationdoes not correctly operate was corrected.

- Parameter file name
When the parameter file with extension was saved automatically, themalfunction to which the extension was missed was corrected.
 
 

=======================================================
- To upgrade SGScan-X from Ver. 1.22 to Ver. 1.23
=======================================================
Then, using the SGScan-X V1.23E Updater, upgrade Ver. 1.20 or Ver.1.21 to Ver. 1.23 Double-clicking "SG Scan-X V1.23E Updater", the updater starts.
Select application that is "SG Scan-X Ver1.2xE".

<Install Files>

[V1.22]

SGScan-X Application Folder
    readme.pdf
    SG Scan-X Ver1.22E ->  SG Scan-X Ver1.23E
       [System] - [Bundle]
@@@@@@@@      - CarbonSCSI.bundle

 

 

 

=======================================================
- To upgrade SGScan-X from Ver. 1.2x to Ver. 1.23
=======================================================
Then, using the SGScan-X V1.23E Updater, upgrade Ver. 1.20 or Ver.1.21 to Ver. 1.23 Double-clicking "SG Scan-X V1.23E Updater", the updater starts.
Select application that is "SG Scan-X Ver1.2xE".


 <Notice for upgrading>

In version 1.22 or highter, the following reference and standard data for RGB have been changed from Version 1.20

1) T AdobeRGB                        2) T sRGB

3) R AdobeRGB                        4) R sRGB

Therefore, after launching the update, the following message that is for confirmation to overwrite these data to newest data appears in a step in the update process. If you have customized these data, we would like you to pay attention to overwriting these data.]

 

 
 

 

 

 

 

 

 

 


Note: Refer to "RGB Input Manual (SG).pdf"in detail.

 

<Install Files>

[V1.21]

SGScan-X Application Folder
    readme.pdf
    SG Scan-X Ver1.21E ->  SG Scan-X Ver1.23E
       [System] - [Bundle]
@@@@@@@@      - CarbonSCSI.bundle

 [V1.20]

SGScan-X Application Folder
    readme.pdf
    SG Scan-X Ver1.20E ->  SG Scan-X Ver1.23E
        [System] - [Error Data]
                           - ErrMsg
                     - [Bundle]
@@@@@@@@         - CarbonSCSI.bundle

 

The upgrade has now been completed.